Control Settings - Husky Altanium Matrix5 User Manual

Table of Contents

Advertisement

User Guide
Table 7-12
Earth Leakage Check
No Heater Detected
Limit

7.6.1.9 Control Settings

The Control Settings fields are described in
Table 7-13
Control Mode
P-Proportional
I-Integral
D-Derivative
Control Settings
v 1.0 — February 2020
Advanced Settings Fields (Continued)
Item
This lets you set the earth leakage checking feature for each zone to ON
or OFF.
Use this field to set the limit for the No Heater Detected alarm. The default
is 0.20 A.
For the system to monitor the current for a No Heater condition:
The zone must be ON.
There are no zone errors.
The actual power value must be 10% or higher. (There are not
enough pulses to calculate an accurate current value at less than
10% power.)
The actual current must be below the 'No Heater Detected Limit'.
The controller must be in a valid state:
-
-
-
-
-
-
-
-
Control Settings Fields
Item
Set the Control Mode to Active Reasoning Technology (ART) or
Proportional Integral Derivative (PID).
ART automatically adjusts the control algorithm applicable to different
heater requirements. If a zone does not control correctly, the system you
switch from the automatically adjusted ART algorithm to an algorithm
that can be manually adjusted (PID).
Refer to
Section 7.7
This is the proportional term value used by the control algorithm.
Possible values are: 0 – 250. Refer to
This is the integral term value used by the control algorithm. Possible
values are: 0 – 250. Refer to
This is the derivative term value used by the control algorithm. Possible
values are: 0 – 250. Refer to
Description
Running
Standby (manual, remote, or delay)
Boost (manual, remote or delay)
Soft Start
Bake Out
Earth Leakage Check
ART
Staging
Table
7-13.
Description
and
Section 7.8
Section
Section
Making Adjustments
for information on ART and PID.
Section
7.8.
7.8.
7.8.
67