Table 9-7
Control Card Over Temperature A control card temperature is more than 76 °C (170 °F).
Fuse 1 Blown
Fuse 2 Blown
Earth Leakage Limit
Lost Thermocouple
Maximum Temp Limit
No Response
Over Current Limit
Receive Data Comm
Rev. Thermocouple
Read Time Out
Abort Conditions — Shutdown Errors
v 1.0 — February 2020
Shutdown Errors (Continued)
Shut Down Error
Fuse 1 on this Intelligent Control Card (ICC
and must be replaced.
Fuse 2 on this Intelligent Control Card (ICC
and must be replaced.
2
ICC
: If the earth leakage is more than the calculated limit or
default value, the earth leakage error is triggered.
3
ICC
: If the measured leakage level is more than the Earth
Leakage Fault Limit value, the earth leakage error is triggered.
This zone has a defective or open thermocouple.
The temperature on this zone has increased above the maximum
value permitted. The usual cause for this is that the switching
device has failed in the closed position and the zone heater
continued to apply heat. The factory setting is 95 °C (200 °F) over
the normal setpoint.
The Altanium has applied 96% to 100% power to this heater for a
set amount of time, and the thermocouple connected to this
zone does not show an indication. The thermocouple is possibly
damaged or the heater power wires are broken.
The current on this zone has increased above the maximum
value permitted.
The data that the zone receives from the Altanium controller has
stopped.
The positive and negative leads from the thermocouple have
been switched or the connections are reversed. As power is
applied, the temperature decreases when it should increase.
Correct this problem at the location where the wires are reversed.
The data that is transmitted from the zone to the Altanium
controller has stopped.
Description
2
3
or ICC
) has opened
2
3
or ICC
) has opened
Heat the Mold