Husky Altanium Matrix5 User Manual page 123

Table of Contents

Advertisement

User Guide
Figure 10-3
Table 10-3
Manual Standby Duration
Timer
Manual Boost Duration Timer
Remote Standby Duration
Timer
Remote Standby Delay Timer
Remote Standby Input Mode
Heats Setup - Control Page 1
v 1.0 — February 2020
Heats Setup - Control Page 1
System Setup Screen - Heats Setup - Control Page 1
Item
The zone temperature decreases for a given time duration or until
a set standby temperature is achieved.
The zone temperature increases for a given time duration or until
a set boost temperature is achieved.
When an external signal has activated the remote standby mode,
the system temperature decreases to the remote standby
setpoint for the duration of the timer setting.
When an external signal has activated the remote standby mode,
the system waits for a set time interval (delay period) until it starts
a decrease in temperature to the remote standby setpoint.
The standby setting is enabled by one of three settings: Trigger,
On/Off, or a Direct signal.
Trigger: Includes a delay timer and duration timer. If the D/I signal
is not sensed, Standby or Boost mode continues until the duration
timer elapses.
On/Off: Includes a delay timer. If the D/I signal is not sensed, the
controller returns to the running state.
Direct: The system changes to Standby until the input signal is not
active. If the input signal is active when the system is started it will
immediately go into Standby mode. Includes a delay timer.