System Status Field - Husky Altanium Matrix5 User Manual

Table of Contents

Advertisement

User Guide
Table 4-1

4.1.3.2 System Status Field

Refer to
Field information.
Table 4-2
System Status Field
v 1.0 — February 2020
Controller Function Buttons
Button
Touch the Stop button to stop the power to all zones. This stops the power
in all system conditions.
Touch the Start button to apply power to the zones that have a configured
setpoint.
Touch the Standby button to put the system in standby mode. If a timer is
active, the time remaining is shown in the status bar. This button is not
available during Active Reasoning Technology (ART) tuning.
Touch the Boost button to put the system in boost mode. If a timer is
active, the time remaining is shown in the status bar. This button is not
available during ART.
Figure 4-1
for the System Status field location.
System Status Field
Button
At Temperature - This gives an indication of what follows:
Flashes while the controller applies heat to the zones as they increase
in temperature to the setpoint.
Solid when all automatic zones are "At temperature".
Off if the controller is in the "Stop" state.
Company Name - The company name is shown.
Altanium Operator Interface
Description
Table 4-2
describes the System Status
Description
17

Advertisement

Table of Contents
loading

Table of Contents