Husky Altanium Matrix5 User Manual page 69

Table of Contents

Advertisement

User Guide
Table 7-2
Temperature Bars
Amperage Bars
Power Bars
Graphical View Screen Overview
v 1.0 — February 2020
Bar Descriptions
Item
Each individual bar on the screen represents one zone of temperature
control. Each bar is labeled above with the zone number. The text shown
at the bottom of each bar is the actual temperature for that zone.
The different colors in each bar have a different meaning.
The green area is the molding window.
The white hairline is the setpoint.
An arrow is the actual temperature.
-
-
The yellow areas in the zone bar are the alarm ranges.
The red and blue areas in the zone bar are the abort ranges.
A blank gray bar shows that the zone is OFF.
The amperage bars are below the zone bars. These show the amperage
that is drawn by each heater. The text shown at the bottom of each bar is
the actual current reading for that zone.
The power bars are located below the amperage bars. These show the
percentage of power that is supplied to the heater. The text at the
bottom of each bar is the actual power output percentage that is
supplied to that zone.
If a zone is in Auto (closed loop) regulation, the bar will fill with
orange depending on the percentage of power output.
If a zone is in Manual (open loop) regulation, the bar will fill with
green depending on the percentage of power output.
If a zone is set to Monitor mode, the bar will remain grey (there is no
power output for zones set to Monitor mode).
Description
If the arrow is yellow, the temperature is not within the graph
range.
If the arrow is black and splits the line, the temperature is at the
setpoint.
Making Adjustments
57