Cycle Input (Heat Control Only) - Husky Altanium Matrix5 User Manual

Table of Contents

Advertisement

Table 12-5
Cycle Mode - Conditions to Stop (UltraSync-E or Altanium Servo Control Installed) (Continued)
UltraSync-E
Heats Running
Engaged
Condition
Condition
Enabled
Enabled
No
Yes
Yes
No

12.4.3.3 Cycle Input (Heat Control Only)

Cycle Input supplies a start or end of cycle signal from the injection molding machine. This
input can be configured as the trigger to log process data on Altanium systems configured
for heats control only.
When this input is selected for use, the controller looks for a rising edge to trigger the start or
end of a cycle.
NOTE:
This feature can be enabled or disabled when you select or deselect the 'In Use' check-box in
the Cycle Input line on the Heats Page 1 tab of the Digital Inputs screen. Refer to
Section
174
v 1.0 — February 2020
Mold Servo
Controller
Engaged
Selection Shown
Condition
Enabled
Yes
Yes
No
Yes
This should be connected to a cyclical signal (the signal goes HIGH to LOW during
each injection cycle)
13.1.3.
Cycle Mode
Conditions
on Screen
If pair of digital inputs (start and end):
End digital input does not go high before the
cycle time limit has expired
UltraSync-E is disengaged or disabled
Mold Servo Controller is disengaged or
disabled
System does not change to timed data collection
If one digital input to start and timer to end data
acquisition:
Start digital input is not high again before the
cycle time limit has expired
UltraSync-E is disengaged or disabled
Mold Servo Controller is disengaged or
disabled
System does not change to timed data collection
If one digital input to start and end data
acquisition:
Start digital input does not go high again
before the cycle time limit has expired
UltraSync-E is disengaged or disabled
Mold Servo Controller is disengaged or
disabled
System does not change to timed data collection
Not applicable
Altanium Matrix5
Conditions to Stop
Cycle Input (Heat Control Only)

Advertisement

Table of Contents
loading

Table of Contents