Table 10-3
Reset Delay Timer in Direct
Mode
Remote Boost Duration Timer
Remote Boost Delay timer
Remote Boost Input Mode
Bake Out Enable
Force Bake Out Enable
Bake Out Alert Enable
Bake Out Limit
Bake Out Power
Bake Out Time Per Cycle
Number of Bake Out Cycles
Bake Out Setpoint
At Bake Out Temperature
Window
112
v 1.0 — February 2020
System Setup Screen - Heats Setup - Control Page 1 (Continued)
Item
This setting lets the delay timer reset if the signal goes low and
then goes high again while in Delay Standby mode.
When an external signal has activated the remote boost mode,
the system temperature increases to the remote boost setpoint
for the duration of the timer setting.
The system initiates the remote boost mode after a set period of
time.
The boost setting is enabled by one of three settings: Trigger,
On/Off, or a Direct signal.
If this parameter is enabled, the system runs the bake out test and
applies a low voltage to remove the moisture in a heater, if
required.
If this parameter is enabled, each zone in the system is baked out
at startup.
If this parameter is enabled, the system stops and generates an
alarm for each zone with a bake-out condition that has not been
cleared during the bake out cycle.
If this parameter is disabled, the system exits the bake-out cycle
and continues the startup sequence.
The system uses this value to trigger a bake-out condition. During
system startup, if a zone is more than this limit, the system starts
the bake out mode.
For ICC
value is 0.2 amps.
For ICC
default value is 200 milliamps.
The system uses this value during the bake out process.
The parameter range is 0 to 25%. The default value is 5%.
The time interval of the bake out cycle. The parameter range is 1
to 30 minutes. The default value is 5 minutes.
The number of tries to bake out the moisture in a heater. The
parameter range is 1 to 5. The default value is 1.
The bake out temperature that the zones must get to during the
bake out process. The default value is 100 °C (212 °F). This is shown
only if ICC
During the bake out process, this parameter sets the temperature
threshold that all zones must get to before the bake out cycle
value starts counting down. The default value is 5 °C (9 °F).
Displays only if ICC
Description
2
cards, the parameter range is 0 to 5 amps. The default
3
cards, the parameter range is 1 to 999 milliamps. The
3
cards are installed.
3
cards are installed.