Table 12-3
Limit
Lower Limit
Upper Limit
Process Outside
Limit
Critical Variable
Action - Heats
Critical Variable
Action - Servos
Delay Limit Check -
Heats Limit
Delay Limit Check -
Servos Limit
Limit Check Active
Process Variable
Selector

12.3.1 Target Settings

Use the Target Settings fields of the screen to enable and configure the zone limit ranges for:
To configure the Target Settings for one or more zones, do the steps that follow:
1.
2.
3.
164
Process Limits Screen Fields (Continued)
Definition
The lowest value the process variable value can be at before there is an "out
of specification" alarm or the system stops. The action is configured in the
Global Settings area of the screen.
The highest value the process variable value can be at before there is an "out
of specification" alarm or the system stops. The action is configured in the
Global Settings area of the screen.
When enabled, this activates the Process Outside Limit (Digital Output 6)
signal when one or more of the process variables goes out of specification
limits. This output is found in the I/O settings screen.
With the Critical check box enabled, this sets the action for the heats when a
process variable goes out of specification. This parameter is only shown when
the controller is configured with heats.
With the Critical check box enabled, this sets the action for the servos when a
process variable goes out of specification. This parameter is only shown when
the controller is configured with UltraSync-E and/or Mold Servo Control.
Sets the amount of time the controller waits while At-Temperature before the
system starts a check of the specification limits.
Sets the number of cycles in Engaged mode that the controller must
complete before the system starts a check of the specification limits.
This is illuminated when the system does the Limit Check operation of the
heats and servos.
Touch this button to select the process variable groups you want to see on
the process Limits screen.
Current
Power
Temperature
Voltage
On the process Limits screen, touch to highlight one or more zones you want to set.
NOTE:
If you select more than one zone, select them by the same category (Current,
Power, Temperature, or Voltage) if they are to be in the same limits.
Touch the Lower Limit field, enter the setting for the category measurement (amps,
percentage, degrees, or volts), and then touch the Accept button.
Touch the Upper Limit field, enter the setting for the category measurement (amps,
percentage, degrees, or volts) and then touch the Accept button.
v 1.0 — February 2020
Altanium Matrix5
Target Settings