User Guide
Figure 13-1
Table 13-3
Table 13-3
Remote Standby
Remote Boost
Remote Start
Remote Stop
Manual Boost
Cooling Lines Not
Enabled
Digital Inputs
v 1.0 — February 2020
Digital Inputs Screen (Heats Page 1)
describes the input signals on the Heats Page 1 screen.
Heats Input Signals (Heats Page 1)
Signal
Puts all zones that have a Remote Standby setpoint into Standby mode
(Lower setpoint) when this input signal is activated.
Puts all zones that have a Remote Boost setpoint into the Boost mode
(Higher setpoint) when this input signal is activated.
Puts the system in Start mode when this signal is remotely activated. This
stays in the state until the STOP key is selected or Remote Stop is
activated.
Puts the system in Stop mode when this signal is remotely activated. This
stays in the state until the START key is selected or Remote Start is
activated.
NOTE:
The system cannot be started when this input is active
Puts all zones that have a Manual Boost setpoint set into Boost mode
(Higher setpoint) when this input signal is activated.
NOTE:
This is the same as if an operator touched the boost key in the
operator interface.
Shows the warning message 'Mold Cooling Lines are not Enabled' on the
screen until the signal has been deactivated. This signal should come
from a thermolator.
NOTE:
If the thermolator is switched off (input signal active), the
warning message is shown.
Description
System Options
179