Table 12-5
Cycle Mode - Conditions to Stop (UltraSync-E or Altanium Servo Control Installed)
UltraSync-E
Heats Running
Engaged
Condition
Condition
Enabled
Enabled
Yes
Yes
170
v 1.0 — February 2020
Mold Servo
Cycle Mode
Controller
Conditions
Engaged
Selection Shown
Condition
on Screen
Enabled
No
Yes
Conditions to Stop
If pair of digital inputs (start and end)
End digital input does not go high before the
cycle time limit has expired
Heats are turned off or not At Temperature
UltraSync-E is disengaged or disabled
System changes to timed data collection
If one digital input to start and timer to end data
collection:
Start digital input is not high again before the
cycle time limit has expired
Heats are turned off or not At Temperature
UltraSync-E is disengaged or disabled
System changes to timed data collection
If one digital input to start and end data collection:
Start digital input does not go high again
before the cycle time limit has expired
Heats are turned off or not At Temperature
UltraSync-E is disengaged or disabled
System changes to timed data collection