User Guide
Table 5-4
Thermocouple
Reading
Power Deviation
Zone Slot
Configuration
Zone Alarm Control
Settings
Mold Cooling Enable
Limit
Remote Load Setup
SPI
Resin Protection
Timer
Autoslave Enable
Autoslave Setup
Soft Start Enable
Soft Start Setup
Earth Leakage Fault
Enable
Earth Leakage Fault
Setup
Bake Out Enable
Bake Out Setup
Screen Security - Heats Page 1 Screen
v 1.0 — February 2020
Screen Security - Heats Page 1 Screen (Continued)
Item
Select the user role that can select and clear the Display Thermocouple
Reading for Manual Zones check box on the System Setup screen.
Select the user role that can select the Setup Alarm button in the Power
Deviation section on the System Setup screen.
Select the user role that can operate the Zone Slot Configuration fields on
the System Setup screen and the fields on the Zone Slot Configuration
screen.
Select the user role that can configure all the parameters in the Zone Alarm
Control area of the System Setup screen.
Select the user role that can change this parameter in the Mold Cooling
Enable area of the System Setup screen.
Select the user role that can configure all the parameters in the Remote
Load Setup dialog window. This option must be purchased before the user
can access this dialog window.
Select the user role that can configure parameters in the SPI area of the
System Setup screen. SPI must be installed on the system.
Select the user role that can set the protect resin timer on the Heats Setup
screen in the System Setup.
Select the user role that can enable the Auto Slave function on the Heats
Setup tab of the System Setup screen.
Select the user role that can set up Auto Slave Power Limit percentage on
the Heats Setup tab of the System Setup screen.
Select the user role that can enable or disable Soft Start on the Heats Setup
tab of the System Setup screen.
Select the user role that can set the Soft Start Minimum Limit temperature
on the Heats Setup tab of System Setup screen.
Select the user role that can enable and disable the System Earth Leakage
Enable check box on the Heats Setup tab of the System Setup screen.
Select the user role that can operate the fields that follow on the System
Setup screen:
Earth Leakage Fault Enable checkbox
Earth Leakage Limit field
Display Earth Leakage Reading check box
Circuit Overload Enable check box
Circuit Test Enable check box
Select the user role that can enable or disable the bake out function on the
Heats Setup tab of the System Setup screen.
Select the user role that can configure the bake out fields on the Heats
Setup tab of the System Setup screen.
Security and Administration
Description
39