Husky Altanium Matrix5 User Manual page 129

Table of Contents

Advertisement

User Guide
Table 10-5
Display Failure Data
At Temperature Minimum
Limit
At Temperature Delay Timer
Enable
At Temperature Delay Timer
At Temperature Delay Timer
Status
Audible Notification Interval
Test Audible Notification
Power Deviation
No Heater Detected Enable
Current Deviation Enable
Current Deviation Limit
Current Deviation Minimum
Limit
Heats Setup - Monitoring
v 1.0 — February 2020
System Setup Screen - Heats Setup - Monitoring (Continued)
Item
This button becomes enabled when the system has completed
the circuit test and failures have been found. Touch the button to
see past test results, so you do not have to run the circuit test
again. If no failures are found, then the button stays disabled.
Refer to
This is the minimum threshold for activating the At-
Temperature signal. The At-Temperature signal is activated
on what follows:
When all active zone temperatures are higher than the
lower alarm limit.
If the alarm band setting is lower than the At-Temperature
Minimum Limit value, then the At-Temperature Minimum
Limit value is used to activate the At-Temperature signal.
Enables or disables the At Temperature Delay Timer feature. This
setting is disabled by default.
This is the time interval that the controller waits before it alerts the
user and IMM that the mold is "At Temperature". The default value
is 00:00:00.
This shows the time that remains as the delay timer counts down.
This sets the time interval between the audible "At Temperature"
alerts. The default is 3 seconds (an alert sounds every 3 seconds).
Use this button to test the "At Temperature" alerts.
When enabled, a power deviation will trigger a power deviation
alarm.
When enabled, this feature causes an alarm when a heater has
failed or is no longer connected to the circuit.
Enables or disables the Current Deviation feature. This setting is
disabled by default.
Used to calculated the current deviation limit that would cause an
error. The default value is 10%. The minimum value is 1% and the
maximum value is 100%.
Used as a minimum value that the calculated limit cannot be more
than. The default value is 0.50 A. The minimum value is 0.10 A and
the maximum value is 5 A.
Description
Section
15.8.
System Setup
117