Husky Altanium Matrix5 User Manual page 185

Table of Contents

Advertisement

User Guide
Table 12-5
Cycle Mode - Conditions to Stop (UltraSync-E or Altanium Servo Control Installed) (Continued)
UltraSync-E
Heats Running
Engaged
Condition
Condition
Enabled
Enabled
No
Yes
No
No
Data Collection Stop Conditions
v 1.0 — February 2020
Mold Servo
Cycle Mode
Controller
Conditions
Engaged
Selection Shown
Condition
on Screen
Enabled
No
No
Yes
No
Conditions to Stop
If pair of digital inputs (start and end):
End digital input does not go high before the
cycle time limit has expired
UltraSync-E is disengaged or disabled
System does not change to timed data collection
If one digital input to start and timer to stop data
acquisition:
Start digital input is not high again before the
cycle time limit has expired
UltraSync-E is disengaged or disabled
System does not change to timed data collection
If one digital input to start and end data
acquisition:
Start digital input does not go high again
before the cycle time limit has expired
UltraSync-E is disengaged or disabled
System does not change to timed data collection
If pair of digital inputs (start and end):
End digital input does not go high before the
cycle time limit has expired
Mold Servo Controller is disengaged or
disabled
System does not change to timed data collection
If one digital input to start and timer to end data
acquisition:
Start digital input is not high again before the
cycle time limit has expired
Mold Servo Controller is disengaged or
disabled
System does not change to timed data collection
If one digital input to start and end data
acquisition:
Start digital input does not go high again
before the cycle time limit has expired
Mold Servo Controller is disengaged or
disabled
System does not change to timed data collection
Data Recording
173

Advertisement

Table of Contents
loading

Table of Contents