Table 10-5
Alarm Sensitivity
Maximum Temperature Limit
No Response Limit
Allow Monitor Regulation for
Selection
Exclude Monitor Zones from
At-Temperature
Wattage Voltage
Supply Configuration
Global Output Power Limit
Earth Leakage Fault Enable
Earth Leakage Limit
Display Earth Leakage Reading When ICC
Circuit Overload Enable
Circuit Test Enable
Auto Power Limiting Enable
Circuit Test State 4 Power
Level
Display Causes and Solutions
Enable
116
v 1.0 — February 2020
System Setup Screen - Heats Setup - Monitoring
Item
The duration of time the system has to stay in an error condition
before an alarm occurs.
The number of degrees over the setpoint that the Maximum
Temperature Alarm occurs.
A global setting that calculates how long the system should apply
96% power or greater without a 5 degree increase in temperature
before an alarm occurs.
Enables the parameter that lets the system change the regulation
mode to "Monitor" for zones in the Quick Set screen.
Enables the parameter that lets the system exclude zones that are
set to "Monitor" regulation from the "At Temperature" condition.
Insert the designed voltage rating of the heaters so the system can
accurately calculate Watt Voltage.
Used to select the supply configuration parameter: Delta 3PH,
Wye 3PH+N, Single Phase, or Integrated TX.
Used to control the maximum output power applied to each zone.
Enable or disable the earth leakage check.
For ICC
limit when the diagnostic process for a zone is complete. The
control card uses a percentage of the current measured during
the test to make the decision when an earth leakage error occurs.
The parameter range is 0 to 100%. The default value is 10%.
For ICC
adjustable range from 1 to 999 mA. The default value is 500 mA.
Enables or disables the circuit overload error. This shows only if
3
ICC
cards are installed.
Enables or disables the circuit test for ICC
When enabled, the controller automatically adjusts the output
power limit values on zones that have oversized heaters attached.
This setting is disabled by default.
This is the power level that is applied during pre-state 4 when the
control card calculates the current during circuit test. The range is
from 20% to 50% and the default value is 50%.
When enabled, the controller stops the system and alerts the user
that failures were detected during circuit test. The controller
shows a dialog window of possible causes and solutions data.
Refer to
Description
2
cards, a percentage used to calculate the earth leakage
3
cards, the value is displayed in milliamps and has an
3
cards are installed, this shows the earth leakage.
Section
15.8.
Altanium Matrix5
3
cards.
Heats Setup - Monitoring