User Guide
Table 12-5
Cycle Mode - Conditions to Stop (UltraSync-E or Altanium Servo Control Installed) (Continued)
UltraSync-E
Heats Running
Engaged
Condition
Condition
Enabled
Enabled
Yes
No
Data Collection Stop Conditions
v 1.0 — February 2020
Mold Servo
Cycle Mode
Controller
Conditions
Engaged
Selection Shown
Condition
on Screen
Enabled
Yes
Yes
Conditions to Stop
If pair of digital inputs (start and end):
End digital input does not go high before the
cycle time limit has expired
Heats are turned off or not At Temperature
Mold Servo Controller is disengaged or
disabled
System changes to timed data collection
If one digital input to start and timer to end data
acquisition:
Start digital input is not high again before the
cycle time limit has expired
Heats are turned off or not At Temperature
Mold Servo Controller is disengaged or
disabled
System changes to timed data collection
If one digital input to start and end data
acquisition:
Start digital input does not go high again
before the cycle time limit has expired
Heats are turned off or not At Temperature
Mold Servo Controller is disengaged or
disabled
System changes to timed data collection
Data Recording