Change The Output Power Limit Setting; Change The Zone Control From Art To Pid; Change P, I Or D Parameter Values - Husky Altanium Matrix5 User Manual

Table of Contents

Advertisement

User Guide

7.6.13 Change the Output Power Limit Setting

The Output Power Limit lets users set the maximum amount of power that can be supplied
to the heaters. The default power limit for all zones is 100%.
To change the Output Power Limit for a zone, do the steps that follow:
1.
2.
3.
4.
5.

7.6.14 Change the Zone Control from ART to PID

The Altanium can automatically adjust the control algorithm to work with different heater
requirements. This control method is Active Reasoning Technology (ART). In some condition,
it may be necessary to switch from the automatically adjusted ART algorithm to an algorithm
that can be manually adjusted. This control method is Proportional/Integral/Derivative (PID).
When you change a zone from ART control to PID control, then you can manually enter
values for the Proportional, Integral, and Derivative parameters. The default control mode for
all zones is ART.
To change the zone control between ART and PID, do the steps that follow:
1.
2.
3.
4.

7.6.14.1 Change P, I or D Parameter Values

If ART has been used on a zone more then one time and could not get the required control,
change the zone to PID control and adjust the three PID parameters to get the required
control.
IMPORTANT!
The zone can be changed back to ART without the loss information. The default settings for
all zones are:
To change the PID settings, do the steps that follow:
1.
2.
Change the Output Power Limit Setting
Touch the zone to be changed.
Touch the Advanced Settings drop-down tab.
Touch the Output Power Limit field.
Type a value from 0% to 100% in the Output Power Limit dialog window.
Touch the Accept button.
Touch the zone to be changed.
Touch the Control Settings drop-down tab.
Touch the Control Mode field.
Select ART or PID in the Control Mode dialog window.
P = 15
I = 10
D = 2
Touch the zone to be changed.
Touch the Control Settings drop-down tab.
v 1.0 — February 2020