10.  TROUBLES THAT DO NOT DISPLAY THE TROUBLE CODE
10.1  Machine is not energized at all (DCPS operation check)
Contents
Trouble type
Machine is not energized at all
Rank
-
Trouble detection condition -
Trouble isolation
-
Relevant electrical parts
Procedure
Step
1
Is a power voltage supplied across CN1-1 and
2 on DCPS?
2
Are the fuses on DCPS conducting?
3
Is DC5 V being output to CN5-1, 2 on DCPS?
4
Is DC24 V being output to CN4-3 on DCPS?
5
The LED on BASEB is blinking?
6
Is DC24 V being output to CN4-6 on DCPS?
10.2  Fusing heaters do not operate
Contents
Trouble type
Fusing heaters do not operate
Rank
-
Trouble detection condition -
Trouble isolation
-
Relevant electrical parts
Procedure
Step
1
Is a power voltage supplied across CN1-1 and
2 on DCPS?
During this time, the right door should be
closed.
2
Is the power source voltage applied across
DCPS CN6?
10.3  Power is not supplied to option
10.3.1  PF-P20/PF-P21
Contents
Trouble type
Power is not supplied to PF-P20/PF-P21.
Rank
-
Trouble detection condition -
Trouble isolation
-
Relevant electrical parts
Procedure
Step
1
Is DC24 V being output to CN1-3, 4 on
PCCB?
L TROUBLESHOOTING > 10. TROUBLES THAT DO NOT DISPLAY THE TROUBLE
• Base board (BASEB)
• DC power supply (DCPS)
Check item
• Right door switch (SW5)
• DC power supply (DCPS)
• Base board (BASEB)
• Fusing unit
Check item
• DC power supply (DCPS)
• PF-P20/PF-P21
Check item
Location of electrical
Result
component
7-V
NO
-
NO
7-S
NO
9-S
NO
-
NO
9-S
NO
Location of electrical
Result
component
7-V
NO
8-T
YES
NO
Location of electrical
Result
component
18-S
NO
L-80
Action
Check the wiring from power outlet to
DCPS CN1.
Replace DCPS.
Replace DCPS.
• Check the wiring from the wall
BASEB to DCPS.
Replace DCPS.
Replace BASEB.
Replace BASEB.
Replace DCPS.
Action
Check the wiring from power outlet to
DCPS to SW5.
Replace the fusing unit.
• Check the wiring from DCPS CN6 to
BASEB CN1E.
Replace DCPS.
Replace BASEB.
Action
Malfunction in paper feed unit.
CODE

Advertisement

loading

This manual is also suitable for:

Bizhub c3300i