bizhub C4000i/C3300i
10. CU-202 (Only for Europe)
10.1 Clean unit (CU-202)
[1]
[2]
[1]
[2]
4. To reinstall, reverse the order of removal.
10.2 UFP filter
1. Remove the clean unit.
F.10.1 Clean unit (CU-202)
[3]
[2]
[1]
[2]
[1]
F DISASSEMBLY/REASSEMBLY > 10. CU-202 (Only for Europe)
1. Push the lock shaft [1] to the left, and remove the clean unit [2].
2. Disconnect the connector [1].
3. Remove the screw [2], and remove the earth cable.
2. Remove the screw [1], and remove the earth cable.
3. Remove two screws [2], and remove the duct [3].
4. Remove two screws [1], and remove the duct [2].
F-45