<Procedure>
1. Using the dedicated image creation tool to create the image data satisfying the specifications mentioned above.
2. To create a data as a zip format file, compress the bin file of the same name (image data) and the Version.txt file (version information) in
one zip file.
NOTE
▪ Character type usable in version information is limited to ASCII (7-bit ASCII). Text strings of up to 21 characters can be used.
3. Save the created data in the root directory of the USB memory.
NOTE
▪ Be careful that the machine is unable to recognize data saved in any directories other than the root directory.
Procedure of data import
1. Connect the USB memory to the USB port of the machine.
2. Touch [Import Config. Data] -> [BootUp Screen].
3. Touch [Set].
NOTE
▪ If a USB memory is not connected or a nonconforming USB memory is connected, "USB NG" is displayed and logo data
cannot be registered.
▪ If the file name of registrable image data does not conform to the above specifications, "File NG" message is displayed and
the data cannot be registered.
4. Check result "OK" is displayed and touch [END].
NOTE
▪ If logo data is already registered, new logo data overwrites the existing logo data.
▪ The color of logo data may look different between the machine control panel and some PC screens. After registering logo
data, restart the machine and check the color of the logo data on the BootUp screen.
▪ To delete registered data, touch [Delete] and make sure that "OK" appears.
10.10.2  Machine Image
• To customize the exterior view of the machine displayed on the control panel.
• Use this function to change the exterior view of the machine displayed on the control panel to the exterior view of the customer business
office according to the user's need.
• Check the version of the installed exterior view data. (When the USB memory is not connected)
NOTE
▪ In the following conditions, import of BootUp Screen data is prohibited.
▪ [Administrator] -> [Security] -> [USB Connection Permission setting] is set to [Restrict].
▪ [Administrator] -> [Security] -> [USB Connection Permission setting] -> [Detail Setting] -> [External Memory(Service)] is set
to [Restrict].
▪ [Administrator] -> [Security] -> [Enhanced Security Mode] is set to "ON".
<Procedure>
1. Save the exterior view data in the root directory of the USB memory.
NOTE
▪ Be careful that the machine is unable to recognize data saved in any directories other than the root directory.
2. Connect the USB memory to the USB port of the machine.
3. Touch [Import Config. Data] -> [Machine Image].
4. Touch [Set].
5. Check result "OK" is displayed.
6. Turn OFF and ON the main power switch.
NOTE
▪ Any exterior view data that has previously been registered will be overwritten by subsequent new data as it is registered.
▪ To delete registered data, touch [Delete] and make sure that "OK" appears.
10.10.3  Custom Auth. Setting
• To install the authentication customize data used to customize the authentication process.
NOTE
▪ Only when one of the following conditions is met, the authentication customize data can be imported.
▪ A USB memory is inserted in the USB port.
▪ [Administrator] -> [Security] -> [USB Connection Permission setting] -> [Detail Setting] -> [External Memory(Service)] ->
[Storage data backup] is set to [ON].
▪ [Administrator] -> [Security] -> [USB Connection Permission setting] -> [Detail Setting] -> [External Memory(Service)] ->
[Firmware Update Parameters] is set to [Allow].
▪ [Administrator] -> [Security] -> [Enhanced Security Mode] is set to "OFF."
<Procedure>
1. Save the authentication customization data in the root directory of a USB memory.
NOTE
▪ Be careful that the MFP is unable to recognize data saved in any directories other than the root directory.
2. Connect the USB memory to the USB port of the machine.
3. Touch [Import Config. Data] -> [Custom Auth. Setting].
4. Touch [Set].
5. Check result "OK" is displayed.
6. Turn OFF and ON the main power switch.
NOTE
▪ The new data will overwrite any existing authentication customization data.
▪ To delete registered data, touch [Delete] and make sure that "OK" appears.
Contents
I-37
I SERVICE MODE > 10. System 2

Advertisement

loading

This manual is also suitable for:

Bizhub c3300i