3.  DEBUG SETTINGS
3.1  Outline
• To configure the settings on log information acquisition performed to analyze the MFP controller's internal operation.
NOTE
▪ Before the procedure, set the switch No. 155 to [00000001] at Bit assignment/[01] at HEX assignment in [Service Mode] ->
[System 2] -> [Software Switch Setting].
Starting procedure
1. Call the initial screen of Service Mode.
2. Press the following keys in this order.
• Stop -> 6 -> 1 -> 8
3. Call the Debug Setting screen.
Example of the Debug Setting screen
Exiting procedure
1. Touch [Exit] on the Service Mode screen.
2. Turn OFF the main power switch. Wait 10 seconds, then turn ON the main power switch again.
3.2  TX Debug Log Settings
• To configure settings used to send debug information via the network.
• To send the information via the network, SMB, FTP, or WebDAV transmission is selectable.
• This item will be displayed only when [Acquiring Mode] is set to "Basic."
Select TX Method
• To select a method used to send via the network.
Setting item
OFF
Select OFF as transmission method of debug information.
SMB
Select SMB as transmission method of debug information.
FTP
Select FTP as transmission method of debug information.
WebDAV
Select WebDAV transmission as transmission method of debug information.
SMB Setting
• To configure settings used in SMB transmission.
Setting item
Host Name
Set the host name for the SMB server.
File Path
Set the file path used in the SMB server communication.
User Name
Set the user name used to access the SMB server.
Password
Set the password used to access the SMB server.
FTP Settings
• To configure settings used in FTP transmission.
Setting item
Host Name
Set the host name of the FTP server.
File Path
Set the file path used in the FTP server communication.
J BILLING SETTING/ENHANCED SECURITY/DEBUG SETTINGS > 3. DEBUG
Contents
Contents
Contents
J-29
Default setting
Setting value
Alphanumeric characters and symbols up
to 253 characters
255 characters maximum
64 characters maximum
64 characters maximum
Setting value
Alphanumeric characters
and symbols up to 253
characters
127 characters maximum