Acer AcerAltos 3102RS User Manual page 217

Ultra-scsi to ultra-scsi raid controller
Table of Contents

Advertisement

When the new controller is connected, it will appear as if it does not
exist. Execute the following steps for the new controller to function.
Press ENT for 2 seconds on the Primary Controller to enter the Main
Menu.
Use t or s to choose "View and Edit
Peripheral Dev..", then press ENT.
Choose "Set Peripheral Device Entry..",
then press ENT.
Choose "Redundant Ctlr Function__",
then press ENT.
The message "Redundant Ctlr Autocfg
Degraded" will appear on the LCD.
Press ENT and the message "Deassert
Reset on Failed Ctlr?" will appear.
Press ENT for 2 seconds and the
controller will start to scan for the new
controller.
The new controller will then start to
initialize.
Once initialized, it will begin acting as the
Secondary Controller.
Chapter 9 Redundant Controller
View and Edit
Peripheral Dev
Set Peripheral
Devices Entry ..
Redundant Ctlr
Function__
Redundant
Ctlr
Autocfg Degraded
Deassert
Reset
on Failed Ctlr?
Redundant Ctlr
Scanning
Initializing...
Please Wait...
AA-3102 v2.11
gggggg
199

Advertisement

Table of Contents
loading