If the "Periodic Drive Check Time" is set to
"Disabled" (the default setting is "Disabled"), the
controller will not be able to detect any drive removal
that occurs after the controller has been powered
on. The controller will only be able to detect drive
removal when a host attempts to access the data on
the drive.
Disk Array Parameters
Press t or s to select "Disk Array
Parameters", then press ENT.
Rebuilding Priority
Press t or s to select "Rebuild Priority",
then press ENT. The current setting will
be displayed on the LCD.
Press t or s to select "Low", "Normal",
"Improved" or "High", then press ENT for
two seconds.
Verification on Writes
Press t or s to select "Verification on
Writes", then press ENT.
(Refer to Chapter 3 section "Verify-after-Write" for more information.)
Chapter 7 General Front Panel Operation
Disk Array
Parameters
..
Rebuild Priority
Low
..
Rebuild Priority
High
?
Verification
on Writes
..
119