6-7-3. RX-45 Board Adjustment
Measuring instruments: Oscilloscope
Frequency counter
Tool:
Extension board EX-670
(For rear board)
Preparations
1. Pull out the RX-45 board using the extension board
EX-670 (for rear board).
2. Connect the frequency counter to CH-2 OUT of the
oscilloscope.
Note:
Start the adjustment after more than 10 minutes from
power ON.
Adjustment
1. Turn OFF the S800/RX-45 (H-3).
2. With the S801/RX-45 (A-5) in the pressed state, adjust
so that the frequency of each TP satisfies the specifica-
tion. Connect GND to E2/RX-45 (D-5).
Measuring Point
Specification
27.0 ± 0.1 MHz
TP100/RX-45 (B-6)
27.0 ± 0.1 MHz
TP101/RX-45 (C-6)
27.0 ± 0.1 MHz
TP200/RX-45 (D-6)
27.0 ± 0.1 MHz
TP201/RX-45 (H-6)
3. Turn ON the S800/RX-45 (H-3).
A
B
C
1
2
3
4
5
RV100
RV102
RV200
RV101
RV103
6
TP100
TP101
FVS-1000 MMP1
Adjustment RV
RV101/RX-45 (B-5)
RV103/RX-45 (C-5)
RV201/RX-45 (D-5)
RV203/RX-45 (H-5)
D
E
F
E2
RV201
TP200
RX-45 board (A side)
6-7. Processor Adjustment (Including BKFV-200)
4. With the S801/RX-45 (A-5) in the pressed state, adjust
so that the frequency of each TP satisfies the specifica-
tion. Connect GND to E2/RX-45 (D-5).
Measuring Point
Specification
25.92 ± 0.10 MHz
TP100/RX-45 (B-6)
25.92 ± 0.10 MHz
TP101/RX-45 (C-6)
25.92 ± 0.10 MHz
TP200/RX-45 (D-6)
25.92 ± 0.10 MHz
TP201/RX-45 (H-6)
5. Turn OFF S800/RX-45(H-3).
G
H
J
RV202
RV203
TP201
Adjustment RV
RV100/RX-45 (B-5)
RV102/RX-45 (C-5)
RV200/RX-45 (C-5)
RV202/RX-45 (G-5)
K
L
6-29