5-1-3. Checking the Imager Movement Table Assembly Control Motor
The operation checks of the stepping motor controlling the imager movement table assembly are per-
formed by inputting commands.
Checking procedure
1. Connect the PC to this unit (CN101/SV-191 board) with the PC connection cable (9 pin-ELCO).
2. Turn on the power of this unit.
Initial setting of the imager movement table assembly starts and stops at the specified position after
turning on the power.
3. Start the HyperTerminal (terminal emulation software) and input "FILM."
"TEST MODE" will be displayed and the test mode of servo system is set.
4. Sequentially after inputting the following command, input "00000000" and the following position
data to check the operation of the motor.
Block
Command
X axis
CAM X
CAM X
Y axis
CAM Y
CAM Y
Z axis
CAM Z
Theta axis
CAM T
CAM T
5. To exit the test mode, input "NORMAL."
FVS-1000 MMP1
Position data
Function
00001000
Imager movement table assembly moves to arrow A direction
FFFFE000
Imager movement table assembly moves to arrow B direction
00001000
Imager movement table assembly moves to arrow C direction
FFFFE000
Imager movement table assembly moves to arrow D direction
FFFFE000
Imager movement table assembly moves to arrow E direction
00001000
Imager movement table assembly rotates to arrow F direction
FFFFE000
Imager movement table assembly rotates to arrow G direction
B
D
E
A
G
Imager movement table
F
assembly
5-1. Test Mode for Servo System Check
C
5-3