Sony FVS-1000 System Maintenance Manual page 40

Multi resolution film scanner, multi resolution telecine, telecine processor, telecine hdtv/sdtv processing boards, telecine log data processor, telecine 16 mm film adaptor kit, telecine optical kit, telecine mounted slide kit, telecine film sound process
Hide thumbs Also See for FVS-1000 System:
Table of Contents

Advertisement

1-10. Installation Procedure
(2) Remove the screw a (B3 x 6), then loosen the screw b (B3 x 6), and then open the cover on the rear
door of the FVS-1000 in the direction of arrow.
(3) Push the "LENS EXCHANGE" button.
(4) Confirm that the lamp changes from flashing to lighting, then open the rear door.
LENS EXCHANGE
button
Screw b
(B3 x 6)
Cover
(5) Release the lock, then pull out the imager movement table assembly.
(6) Turn the lens mount lever in the direction of arrow, then remove the protection cap from the imager.
Protection cap
Imager
1-28
Screw a
(B3 x 6)
Lens mount lever
Lock
Rear door
Imager movement table assembly
Lock
FVS-1000 MMP1