Sony FVS-1000 System Maintenance Manual page 160

Multi resolution film scanner, multi resolution telecine, telecine processor, telecine hdtv/sdtv processing boards, telecine log data processor, telecine 16 mm film adaptor kit, telecine optical kit, telecine mounted slide kit, telecine film sound process
Hide thumbs Also See for FVS-1000 System:
Table of Contents

Advertisement

3-4. Replacement of Periodic Replacement Part
6. Adjusting the E guide height
(1) Loosen the two screws shown in the figure to move the
E guide stay 35 smoothly.
(2) Adjust the E guide height as the following procedures.
For gate base (35) assembly:
While keeping the state of (3) of step 5, insert the
thickness gauge with 0.03 mm thick between the E
guide flange and E guide stay 35. And while pushing
the E guide flange toward the height gauge, and then
tighten the two screws.
For gate base (16) assembly:
While keeping the state of (3) of step 5, push the E
guide flange toward the height gauge, and then tighten
the two screws. (Do not insert the thickness gauge
between E guide flange and E guide stay 16.)
E guide hight gauge
E guide stay 35
E guide flange
Loosen these screws
3-30
Thickness gauge
E guide stay 35
(3) Check the specifications of (4) and (5) of step5 again.
(4) After checking the specifications, apply the locking
compound to the two screws.
7. Installing the integrator assembly
Install the integrator assembly to the gate base (35)
assembly.
8. Installing the gate base (35) assembly
Install the gate base (35) assembly.
FVS-1000 MMP1