6-10. BKFV-500 Adjustment

6-10-2. Film path Adjustment

Measuring instruments: Oscilloscope
Tool:
P35-SF-B200 (SMPTE)
Adjustment
1. If the waveform shown in Fig. 1 is displayed, turn the
audio head flange and adjust so that the waveform
becomes linear.(Refer to Section 6-10-1 (2).)
n
When rotating the audio head flange adjustment, adjust
so that the specification in Section 6-10-1 (2) is
satisfied.
2. If the waveform while the film is running shown in
Fig. 1 fluctuates, loosen the set screw of the guide
roller 4, adjust the bearing retainer within the range of
± 90 degrees to minimize the fluctuation.
Guide roller 4
Setscrew
Bearing retainer
Fig. 1
6-38