Sony FVS-1000 System Maintenance Manual page 56

Multi resolution film scanner, multi resolution telecine, telecine processor, telecine hdtv/sdtv processing boards, telecine log data processor, telecine 16 mm film adaptor kit, telecine optical kit, telecine mounted slide kit, telecine film sound process
Hide thumbs Also See for FVS-1000 System:
Table of Contents

Advertisement

1-11. Installation of Optional Units
Preparations
(1) Set to the STANDBY OFF mode.
(2) Turn OFF the power.
1. Removal of the FTP panel
Remove FTP panels A, B, and D. (Refer to Section 2-7-4.)
2. Removal of the S-AU assembly
(1) Remove the S-AU assembly. (Refer to Section 4-6.)
(2) Remove the two screws, and remove the S guide installation panel from the S-AU assembly.
(3) Loosen the setscrew, and remove the bearing retainer.
(4) Remove the bearing, guide roller, spacer, and compression spring.
Guide rollers
Bearings
Bearing retainers
Setscrews
1-44
S-AU assembly
Compression spring
Spacers
Bearings
Screws 4 x 10
S guide installation panel
FVS-1000 MMP1