Cleaning The Flc Assembly - Sony FVS-1000 System Maintenance Manual

Multi resolution film scanner, multi resolution telecine, telecine processor, telecine hdtv/sdtv processing boards, telecine log data processor, telecine 16 mm film adaptor kit, telecine optical kit, telecine mounted slide kit, telecine film sound process
Hide thumbs Also See for FVS-1000 System:
Table of Contents

Advertisement

3-3. Cleaning the Optical System

3-3-3. Cleaning the FLC Assembly

1. Remove the gate base (35) assembly.
(Refer to Section 3-2-1.)
2. Remove the integrater assembly from the gate base
(35) assembly.
3. Loosen the four screws (with stopper), and pull out the
lamp house assembly. (Refer to Section 3-4-1.)
4. Loosen the three screws (with stopper), and remove
the lamp house cover. (Refer to Section 3-4-1.)
Integrater assembly
(1) Blow off the dusts on the glass surface (2 locations) of
the integrater assembly using the air blower for optical
use.
(2) For stubborn dusts which cannot be removed using the
air blower, clean with a cleaning cloth moistened with
cleaning liquid for optical use.
n
After cleaning, install the integrater assembly after the
cleaning liquid has evaporated completely.
Gate base (35) assembly
Glass
3-10
Glass
Integrater assembly
F-FLC
n
Do not push the glass side of the F-FLC with force or hit it
with a hard object as this may cause the performance of the
FLC assembly to drop considerably, or disable use.
(1) Blow off the dusts on the glass side of the F-FLC
using the air blower for optical use.
(2) For stubborn dusts which cannot be removed using the
air blower, clean with a cleaning cloth moistened with
cleaning liquid for optical use.
n
After cleaning, install the lamp house assembly after
the cleaning liquid has evaporated completely.
F-FLC
Lamp house assembly
FVS-1000 MMP1

Advertisement