4-11. Replacing the Power Supply for Processor

Preliminary Preparations
Open the door at the bottom of the unit.
Removal
1. Removing the power supply for the
processor
(1) Turn off the AC power supply which supplies
the power to the FVS-1000.
n
To prevent an electric shock, be sure to turn
off the power of the AC power supply which
supplied the power to the FVS-1000 before
removing.
(2) Remove the four screws.
(3) Holding the handle of the power supply for
the processor, pull out the power supply.
Installation
2. Installing the power supply for the
processor
(1) Align the connector at the rear of the power
supply for the processor and the connector of
the DD-33 board, and push in.
n
Firmly push in the connector at the rear of the
power supply to the connector of the DD-33
board until they connect.
(2) Secure the power supply for the processor
using four screws.
FVS-1000 MMP1
Power supply
connector
Handles
PSW4 x 8
PSW4 x 8
Handles
Power supply
for processor
PSW4 x 8
4-11. Replacing the Power Supply for Processor