Sony FVS-1000 System Maintenance Manual page 224

Multi resolution film scanner, multi resolution telecine, telecine processor, telecine hdtv/sdtv processing boards, telecine log data processor, telecine 16 mm film adaptor kit, telecine optical kit, telecine mounted slide kit, telecine film sound process
Hide thumbs Also See for FVS-1000 System:
Table of Contents

Advertisement

6-6. Lamp House Adjustment
Adjustment
Note: In the following, [ENTER] means the ENTER key.
1. Secure the gate base and integrating sphere for 35 mm
to the lamp house and turn ON the power of the FTP.
(Lamp turns ON)
n
When adjust the procedure 8. , perform warm-up
running for 10 minutes over after the lamp turns ON.
2. Wait for the hyper terminal window to display
"READY".
3. Set the timer mode.
Select "timer" on the PC and press [ENTER].
4. Set all four parameters on the lamp control to [FFFF].
Display menu 02 on the control panel, and control
knob of "MASTER", 'RED", "GREEN" and "BLUE".
5. Pre-adjust RV401, RV431 and RV461 of the LC-35
board.
(1) Connect the oscilloscope to the following check
points, and adjust the offset RV.
Measuring Point
Specification
IC403-14 pin/LC-35
Level of higher value: R (gain)
3 ±0.5 V dc
IC433-14 pin/LC-35
Level of higher value: G (gain)
3 ±0.5 V dc
IC463-14 pin/LC-35
Level of higher value: B (gain)
3 ±0.5 V dc
IC403, IC433, IC463
14pin
6-22
6. Adjust the R (gain), G (gain) and B (gain) of the inte-
grating sphere so that the center position of the gain is in
the electrical center of the RV(Shown in "C" of the
figure).
n
Each RV of the R (gain), G (gain) and B (gain) is a
360-degree rotation type and without stopper.
(1) Connect the oscilloscope to the following check
points, and adjust the corresponding RV while watch-
ing the level of higher value.
Measuring point
IC403-14pin/LC-35
IC433-14pin/LC-35
IC463-14pin/LC-35
(2) Locate the point "A" as shown in the figure so that the
level of higher value changes from maximum to
minimum.
(3) Rotate the RV to 180 degrees from the point "A"
shown in the figure.
This location is the point "C" shown in the figure, this
Adjustment RV
point is in center of gain.
RV401/LC-35
RV431/LC-35
RV461/LC-35
A
B
1
IC463
IC433
RV461
RV431
2
3
TP305 TP303 TP301
4
5
LC-35 board (Suffix -13 and higher, Side A)
Adjustment RV
electrical center
electrical center
electrical center
Level of higher value
5V
C
Rotate to
180-degree
C
D
IC403
RV401
CN15
Name
R (gain)
G (gain)
B (gain)
A
360-degree
Direction of RV rotate
E
F
FVS-1000 MMP1

Advertisement

Table of Contents
loading