Perform the periodic checks and maintenance in order to ensure correct function and performance and
also to extend the life of the film.
3-1.

Periodic Inspection List

3-1-1. Telecine Main Unit (FVS-T1000)

The time shown below is not the warranted time of the part. Use the following time as reference to plan
the maintenance and inspection. The time for the part replacement depends on circumstances and
conditions where the system is operated.
Inspection item
Lamp house
Lamp
(with plastic case)
Filter assembly
IR/UV cut filter
Gate base (35) assembly
Film guide (G) assembly
E guide roller assembly
Gate base (16) assembly
Film guide (G) assembly
E guide roller assembly
Retainer (35) assembly
Film pad (35) assembly
Retainer (16) assembly
Film pad (16) assembly
Film drive
I sprocket 35/16
C sprocket 35/16
F guide roller
P roller 35 assembly
P roller 16 assembly
Guide roller 35/16
Ball bearing (1480ZZ)
Air filter
Element of the filter
regulatot
Element of the mist
separator
Loop sensor
Light sensor
PT roller
Static electricity elimirator
FVS-1000 MMP1
Section3

Periodic Check and Maintenance

Inspection time (h)
(Lamp lighting time)
1000
2000
3000
4000
R
R
R
R
R : every 6000 h
R : every 7000 h
R : every 25000 h
C
C
C
C
R : every 25000 h
C
C
C
C
R : every 25000 h
C
C
R : every 25000 h
C
C
R : every 25000 h
C
C
R : every 25000 h
C
C
R : every 25000 h
C
C
R : every 25000 h
R : every 25000 h
R : every 25000 h
R : every 25000 h
R :Every two years or when the pressure decreases
to 0.1 MPa (1 kgf.m).
R :Every two years or when the pressure decreases
to 0.1 MPa (1 kgf.m).
C : every 7500 h
C : Any time
R : every 1000 h
C : every 1000 h
5000
6000
7000
8000 Part number
R
R
R
R
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C : Inspection and cleaning
R : Replacement
Replaced part
Amount
Referring
page
1-517-872-11
1
3-15
A-8321-649-B
1
3-20
1-758-295-11
1
3-22
X-3605-757-2
2
3-27
X-3608-139-1
2
3-28
X-3605-757-2
1
3-27
X-3608-140-1
2
3-28
X-3605-375-3
1
3-31
X-3605-754-2
1
3-31
3-617-172-02
2
3-18
3-617-173-02
2
3-18
X-3605-756-1
4
3-18
X-3605-386-3
8
3-23
X-3605-951-1
8
3-23
3-617-343-03
12
3-26
3-698-693-02
24
3-26
3-636-379-01
3-32
3-636-380-01
3-32
1-476-254-11
2
3-628-104-01
4
3-6
1-251-980-11
1
3-7
3-1