Sony FVS-1000 System Maintenance Manual page 244

Multi resolution film scanner, multi resolution telecine, telecine processor, telecine hdtv/sdtv processing boards, telecine log data processor, telecine 16 mm film adaptor kit, telecine optical kit, telecine mounted slide kit, telecine film sound process
Hide thumbs Also See for FVS-1000 System:
Table of Contents

Advertisement

6-11. BKFV-410
5. Place the mirror adjusting tool on the gate base
assembly as shown in the figure.
Chart holding tool
Resolution chart
6. Select the mode number 18 from the control panel, and
set the IRIS data to around "5600".
7. Adjust the screen is turned black and white using ND
filter (mode number 19) and lamp control (mode
number 02).
8. Adjust the camera position (mode number 08 and 18)
so that the square chart of the resolution chart is shot
to the full screen of the monitor.
6-42
Mirror adjusting tool
Gate base (35)assembly
9. When adjusting the horizontal direction on the monitor
screen, loosen the adjusting screw and rotates the
anamo block of the lens shown in the figure so that the
square chart turns rectangle.
. When the top of the rectangle is leaned to the right
(Fig. 1):
Rotate the ring to A direction.
. When the top of the rectangle is leaned to the left
(Fig. 2):
Rotate the ring to B direction.
(Fig. 1)
(Fig. 2)
Master zoom lens
Adjusting screw
A
B
10. Tighten the adjusting screw loosened in step 9.
11. Tighten the three setscrews loosened in step 2 using L-
shaped wrench (1 mm).
12. Apply the locking compound to the three setscrews
removed in step 1, and tighten these screws to the lens
using L-shaped wrench (1.5 mm).
13. Check the generating line is not slanting using the
resolution chart again.
Aspect conversion lens
FVS-1000 MMP1