Installing the Bottom Library Module in a Rack

|
|
|
|
|
Figure 3-19. Gear racks positions (rear gear racks shown)
v Top hole of the first EIA (see Figure 3-14 on page 3-16)
v Top hole of the second EIA in the vertical rack rails (see Figure 3-14 on page
3-16)
6. Repeat this procedure for the other rail.
After you've prepared the modules for installation, start with the module that will
be at the bottom of the library.
Note: The bottom module in the library is the only module that should have a
bottom cover installed. The top module is the only module that should have
a top cover installed.
1. For all configurations, ensure that the front and rear gear racks are locked in
the upper position. See 2 in Figure 3-19.
1
1
Gear rack in the down
position
2. With a person on each side of the module, lift the module with the sling
provided (see Figure 3-20 on page 3-22).
2
2
Gear rack in the up position
Chapter 3. Installing A New Library in a Rack
3-21