Figure 3-31. Control Module Power Supply

Cabling the Library

|
|

Cabling a 5U Control Module

3-32
TS3310 Tape Library Setup and Operator Guide
1
4
3
1. Replace the power supply component by sliding it into the power supply slot.
First, grasp the handle ( 1 in Figure 3-31) while supporting the power supply
component from underneath. Then, line up the power supply component with
the guides in the power supply slot, and carefully push it into the library.
2. Tighten the two thumb screws ( 2 in Figure 3-31) on the power supply
component by turning them clockwise.
3. Repeat this procedure for each library power supply.
At this point in the installation procedure, install the module-to-module
communication cable, the module communication terminators, the
customer-supplied Ethernet cable, the drive sled cables, and the power supply
cabling. Select and perform one of the following cabling procedures, depending
upon your library configuration:
v "Cabling a 5U Control Module"
v "Cabling with SCSI Cables" on page 3-33
v "Cabling with Fibre Channel Drives" on page 3-35