T068: Destination element for a move media is full

Description
Detection Scenarios
Root Causes
Possible CRU Replacements
Resolution

T069: Source element for a move media is empty

Description
Detection Scenarios
Root Causes
Possible CRU Replacements
Resolution

T070: Logical library control path failed

Description
11-26
TS3310 Tape Library Setup and Operator Guide
The robot has attempted to put to a drive, I/O, or storage
element and has determined that the element is full. This is
distinctly NOT a SCSI illegal request situation. At the
beginning of the move media, the library inventory has
indicated that the destination element was in an empty
state to allow it to be a valid destination. During recovery
operations, the library has concluded that the cell is
obstructed by a piece of media. Any failure that is not
thought to be a piece of media in the destination should
not be mapped to this ticket.
The destination element for a move media is full with a
LABELED cartridge. Library inventory does not know that
the cell is full.
Inventory has not occurred since cartridge was placed in
element by some manual operator intervention.
Tape Cartridge
Perform "DR020: Re-inventory the Library" on page 11-40.
The robot has attempted to get from a drive, I/O, or
storage element and has determined that the element is
empty. This is distinctly NOT a SCSI illegal request
situation. At the beginning of the move media, the library
inventory has indicated that the source element was not in
an empty state and it was a valid source for a move media
command. During recovery operations, the library has
concluded that the cell is genuinely empty. Empty is
defined as NOT containing a cartridge with a readable
volume serial number.
The library fails to successfully get a cartridge during a
move media. The cartridge present sensor in the Picker
indicates no cartridge at the conclusion of a GET and a
subsequent inventory scan of the cell indicates that no
cartridge is present.
Inventory has been manually changed since last robotic
inventory. Cartridge was removed from or moved within
the system.
Tape Cartridge
Perform "DR020: Re-inventory the Library" on page 11-40.
The library media changer control path through a drive has
failed. The host that owns and runs the logical library can
no longer be expected to be able to control the library. The
control path must be fixed or a user could choose to switch
the control path to a different drive within the same logical
library.