IBM System Storage TS3310 Setup And Operator Manual page 315

Tape library
Hide thumbs Also See for System Storage TS3310:
Table of Contents

Advertisement

Table C-1. Library Sense Data and associated ASC/ASCQs (continued)
Sense
Key
ASC
ASCQ
B
49h
00h
B
4Ah
00h
B
4Bh
00h
B
4Eh
00h
4
53h
00h
4-5
*53h
*01h
5
*53h
*02h
5
53h
81h
4
53h
82h
4
53h
83h
4
*83h
*00h
5
*83h
*02h
5
*83h
*03h
5
*83h
*04h
5
*83h
*05h
Description
Invalid message error
Command phase error
Data phase error
Overlapped commands attempted
A drive did not load or unload a tape.
A drive did not unload a cartridge.
Medium removal prevented.
I/O Station door is open.
Cannot lock the I/O Station.
Cannot unlock the I/O Station
Label too short or too long
Barcode label questionable
Cell status and barcode label questionable
Data transfer element not installed.
Data transfer element is varied off and
not accessible for library operations.
Required Action
A command failed because an invalid
message was received by the drive.
Failure Isolation Procedure
If the problem persists, go to "Contacting
IBM Technical Support" on page 10-17.
A command could not be executed because
too many parity errors occurred during the
Command phase.
Failure Isolation Procedure
If the problem persists, go to "Contacting
IBM Technical Support" on page 10-17.
A command could not be executed because
too many parity errors occurred during the
Data phase.
Failure Isolation Procedure
If the problem persists, go to "Contacting
IBM Technical Support" on page 10-17.
An initiator attempted to send a command
to the drive even though it already had
another command being processed in the
drive.
Failure Isolation Procedure
If the problem persists, go to "Contacting
IBM Technical Support" on page 10-17.
An attempt to load or eject the cartridge
failed.
Failure Isolation Procedure
See "Contacting IBM Technical Support" on
page 10-17.
Appendix C. Sense Data
C-7

Advertisement

Table of Contents
loading

Table of Contents