Imm Error Messages Detected When A Max5 Is Attached To The Server - IBM x3690 X5 Service Manual

Hide thumbs Also See for x3690 X5:
Table of Contents

Advertisement

IMM error messages detected when a MAX5 is attached to the
server
The following table describes the IMM error messages and suggested actions to
correct the detected problems when a MAX5 is attached to the server: See
"System-event log" on page 167 and Table 9 on page 167 for additional information
about the fan event messages and the device on which the fan is located.
Table 11. IMM error messages detected when MAX5 is attached to the server
Event ID
800b0008-1382xxxx
800b0108-1381xxxx
800b0108-1382xxxx
800b0308-1382xxxx
800b050a-1e86xxxx
816f0507-2584xxxx
806f0507-2584xxxx
Message
Redundancy MEU Power
Unit has been restored
Redundancy lost for Power
Group 1 has asserted
Non-redundant:Sufficient
Resources from Redundancy
Degraded or Fully
Redundant for
[RedundancySetElementName]
has asserted
Non-redundant:Insufficient
Resources for
[RedundancySetElementName]
has asserted
Redundancy Power Group 1
has been restored
Failure no longer predicted
on EPOW fault
2S CPU has recovered from
a configuration mismatch
2S CPU has a configuration
mismatch
CPU Type Check has
recovered from a
configuration mismatch
Severity Description
Info
MAX5 power supply
has been installed.
Error
Power supply
redundancy has been
lost.
Info
Redundancy set has
transitioned from
redundancy
degraded or fully
redundant to
non-
redundant:sufficient.
Error
Cooling zone alert.
Info
Redundant power
has been restored.
Info
The EPOW fault
failure is no longer
predicted.
Info
The configuration
mismatch on 2S CPU
has recovered.
Error
A configuration
mismatch has
occurred on 2S CPU.
Info
The CPU Type Check
configuration
mismatch has
recovered.
Action
Information only; no
action is required.
Install additional
power supplies.
MAX5 power
supplies are
non-redundant.
MAX5 cooling zone:
Inspect and replace
the failed fans in
MAX5.
No action;
information only.
No action;
information only.
No action;
information only.
1. Check to make
sure that matched
microprocessors
are installed. See
"Replacing a
microprocessor
and heat sink" on
page 351 for
information about
installation
requirements.
2. (Trained service
technician only)
Replace the
microprocessor.
No action;
information only.
221
Chapter 3. Diagnostics

Advertisement

Table of Contents
loading

Table of Contents