Conventions

This manual describes how to safely operate the CM-M6 using a specific procedure to perform measurement.
· Viewing Pages
Symbols used in this manual are explained below.
* Explanatory pages are constructed as follows. (The content of the explanatory illustration will differ from the
actual page.)
* Display screenshots used in the explanations may include different content and values, and may have a different
layout than the actual display.
Procedure
Indicates an
operating procedure.
Settings
Describes ranges and
provides
explanations
regarding settings for
the screen in
question.
Memo
Provides useful
information,
supplementary
explanations, and
similar details.
Notes
Provides essential
information for
correct operation of
the instrument.
Always read this
information before
operating the
instrument.
Instrument Firmware Version
The version of the instrument firmware can be confirmed on the <Instrument info.> screen. For details, refer to
page 98 "Displaying the Instrument Information" in this manual.
9
Annual Calibration Messages
As the time for periodic calibration approaches, the instrument shows a message reading "Regularly scheduled
device calibration is required. Please contact the nearest service center." at start-up to recommend annual service
recalibration.
The annual calibration message can be turned OFF from the MENU.
Although the annual calibration message can be hidden, it is recommended to accept our recalibration
Notes
service.
Display of the annual calibration message is set to "ON (Display)" under the initial settings.
Memo
Operating Procedure
Start the procedure from the <Setting> - <Calibration setup> screen.
1
Press [MENU].
The <Annual calibration> screen is displayed.
Settings
OFF : Do not show the annual calibration message
{
even if the next calibration date is near.
ON
: Show the annual calibration message when the
{
next calibration date approaches.
2
Use [] or [] to move the cursor to select "OFF" or
"ON".
If the annual calibration notification message is set to ON,
Memo
the annual calibration message will be displayed when the
specified day approaches. The date of the next calibration is
specified under the initial settings or during KONICA
MINOLTA calibration service (or maintenance) and cannot be
changed.
3
Press the [Confirmation] key.
The selection is confirmed and the screen returns to the
<Setting> screen.
If [ESC] is pressed without pressing the [Confirmation]
Notes
key, the settings will not be changed and the screen will
return to the <Setting> screen.
Start screen
Sample
0002 TARGET-2
Indicates the initial
Setting
3
Calibration setup
screen from which
Calibration interval
8 (hour)
the operation is
Annual calibration
ON
commenced.
Sample
0002 TARGET-2
Setting
Calibration setup
Annual calibration
Calibration interval
Screenshot
OFF
8 (hour)
ON
Annual calibration
ON
Indicates the state of
Next date
2016/01/01
the screen when the
operation described
in the procedure to
the left is carried out.