[Pr. Pd11_Input Filter Setting (*Dif)]; [Pr. Pd12_Function Selection D-1 (*Dop1)] - Mitsubishi Electric MELSERVO-J5 MR-J5-G User Manual

Ac servo system
Hide thumbs Also See for MELSERVO-J5 MR-J5-G:
Table of Contents

Advertisement

[Pr. PD11_Input filter setting (*DIF)]

Initial value
00000007h
[Pr. PD11.0_Input signal filter selection]
Initial value
7h
Setting value
0
1
2
3
4
5
6
7
8
9
A
B
This filter is disabled for pins to which TPR1, TPR2, or TPR3 is assigned.

[Pr. PD12_Function selection D-1 (*DOP1)]

Initial value
00000101h
Set the servo motor thermistor to either enabled or disabled.
[Pr. PD12.3_Servo motor thermistor - Enabled/disabled selection]
Initial value
0h
0: Enabled
1: Disabled
This servo parameter is enabled when a servo motor with a built-in thermistor is used. When a servo motor without a
thermistor is used, the servo parameter is disabled (temperature monitoring disabled/alarm disabled) regardless of the setting
value.
No alarm is detected in motor-less operation.
When the temperature monitoring of the motor thermistor is disabled, "9999 °C" is displayed.
1 SERVO PARAMETER DETAILS
88
1.5 I/O setting servo parameters group ([Pr. PD_ _ ])
Setting range
Refer to the relevant detail No.
Setting range
Refer to the text
Filtering time [ms]
No filter
0.500
1.000
1.500
2.000
2.500
3.000
3.500
4.000
4.500
5.000
5.500
Setting range
Refer to the relevant detail No.
Setting range
Refer to the text
Setting method
Common
Ver.
A0
Setting method
Each axis
Ver.
A0
Ver.
Refer to the relevant detail No.
Ver.
Refer to the relevant detail No.