Vdc Voltage Supply - B&R Panel PC 2100 User Manual

Built-in devices
Hide thumbs Also See for Panel PC 2100:
Table of Contents

Advertisement

2.4.2 +24 VDC voltage supply

The 3-pin male connector required for the power supply interface is not included in delivery. It can be ordered from
B&R using model number 0TB103.9 (screw clamps) or 0TB103.91 (cage clamps).
The pinout is listed in the following table. The supply voltage is protected internally by a soldered fuse (15 A, fast-
acting) to prevent damage to the device in the event of an overload (fuse replacement necessary) or if the voltage
supply is connected incorrectly (reverse polarity protection -> fuse replacement not necessary). The device must
be returned to B&R for repairs if the fuse is blown in the event of an error.
Protected against reverse polarity
Pin
1
2
3
Model number
Short description
Terminal blocks
0TB103.9
Male connector 24 V 5.08 3-pin screw clamps
0TB103.91
Male connector 24 V 5.08 3-pin cage clamps
Electrical characteristics
Nominal voltage
Nominal current
Starting current
Electrical isolation
Uninterruptible power supply
2.4.2.1 Grounding
Caution!
Functional ground (pin 2 of power supply and ground connection) must be kept as short as possible
and connected to the largest possible wire cross section at the central grounding point (e.g. the control
cabinet or system).
The ground connection is located on the interface side of the Panel PC system.
The ground connection must be used, for example, to fasten a copper strip to a central grounding point in the
control cabinet or system where the device is installed. The largest possible conductor cross section should be
used (at least 2.5 mm²).
Panel PC 2100 user's manual V1.11
+24 VDC power supply
Description
+
Functional ground
-
Table 36: +24 VDC voltage supply connection
24 VDC ±25%
3.5 A
Typ. 6 A; max. 10 A for <300 μs
Yes
No
Grounding
Technical data • Complete system
3-pin male power supply connector
+24 VDC power supply
43