Technical data • Complete system
2.2.1.3 Maximum ambient temperature for typical operation
Information regarding typical conditions
• The total power of all system unit USB interfaces is limited to 1 W.
• 2x Gigabit Ethernet
• No permanent 100% processor load and graphics load
• The power consumption of the entire system is limited to 45 W. For information about the power consump-
tion of individual components, see 2.3.2 "Power calculation".
All specifications are valid for non-condensing operation.
AP9x3 display units
AP1000 display units
CFast cards
Interface options
30
All temperature values in degrees
Celsius (°C) at 500 m above sea level, non-condensing.
The typical ambient temperature is typically derated by 1°C
per 1000 meters (starting at 500 meters above sea level).
Maximum ambient temperature for typical operation
What else can also be operated at the typ.
ambient temperature, or are there any limits?
5AP923.1215-00
5AP923.1505-00
5AP923.1906-00
5AP933.156B-00
5AP933.185B-00
5AP933.215C-00
5AP933.240C-00
5AP1120.0573-000
5AP1151.0573-000
5AP1120.0702-000
5AP1120.101E-000
5AP1120.1043-000
5AP1180.1043-000
5AP1181.1043-000
5AP1182.1043-000
5AP1120.1214-000
5AP1120.121E-000
5AP1120.1505-000
5AP1180.1505-000
5AP1120.156B-000
5AP1120.1906-000
5CFAST.xxxx-00 ≥ Rev. E0
5CFAST.xxxx-10
5ACCIF01.FPCC-000
5ACCIF01.FPLK-000
5ACCIF01.FPLS-000
5ACCIF01.FPLS-001
5ACCIF01.FPSC-000
5ACCIF01.FPSC-001
5ACCIF01.ICAN-000
Table 20: Maximum ambient temperature for typical operation
E3815
E3825
E3826
E3827
1.46 GHz
1.33 GHz
1.46 GHz
1.75 GHz
1.91 GHz
60
60
60
55
50
50
50
50
50
50
50
50
50
50
50
50
40
40
40
40
40
40
40
40
55
55
55
55
55
55
50
50
50
50
50
50
50
50
55
55
55
55
55
55
55
55
55
Panel PC 2100 user's manual V1.11
E3845
55
50
50
50
40
40
50
50