The material used for the cable should have all or most of the following properties in order to achieve an optimal
transfer rate.
CAN cable
Signal lines
Cable cross section
Wire insulation
Conductor resistance
Stranding
Shield
Grounding line
Cable cross section
Wire insulation
Conductor resistance
Outer sheathing
Material
Features
Complete shielding
3.5.1.3.4 Pinout X2X Link master interface
The X2X Link master interface on the system unit is referred to as IFx.
The electrically isolated X2X Link master interface is a 10-pin connector.
Pin
1
2
3
4
5
6
7
8
9
10
1)
The interfaces, etc. available on the device or module have been numbered as such for easy identification. This numbering may differ from that used by
the particular operating system.
2)
This interface can only be used in Automation Runtime and is referred to as IF2 in Automation Studio / Automation Runtime. It is not a "PC interface" and
therefore not shown in BIOS.
3.5.1.3.5 Shielding
For the interfaces on the 10-pin female connector, the interface shield can be put on pin 2 of the female connector.
A functional ground connection, which can also be used for the cable shields, is located on the interface plate of
the system unit.
Panel PC 2100 user's manual V1.11
2x 0.25 mm² (24 AWG / 19), tinned copper stranded wire
1x 0.34 mm² (22 AWG / 19), tinned copper stranded wire
Table 108: CAN cable requirements
X2X Link master - IFx
Assignment
X2X H
Shield
X2X L
X2X GND
-
-
-
-
-
-
Table 109: 5ACCIF01.FPCC-000 - X2X Link master interface
Technical data • Individual components
Property
PE
≤82 Ω/ km
Wires stranded in pairs
Paired shield with aluminum foil
PE
≤59 Ω/km
PUR mixture
Halogen-free
From tinned copper wires
1)2)
10-pin, male
1
3
5
2
4
6
7
9
8 10
127