System stop error codes
Incorrect configuration or defective hardware can cause a system stop error.
The error code is indicated by the red Error LED using four switch-on phases. Each switch-on phase has a duration
of either 150 ms or 600 ms. The error code is repeated every 2 seconds.
Error description
RAM error:
The interface is defective and must be replaced.
Hardware error:
The interface or a system component is defective and must be replaced.
Key
•
−
Pause
3.5.4.3.4 Shielding
For the interfaces on the 10-pin female connector, the interface shield can be put on pin 2 of the female connector.
A functional ground connection, which can also be used for the cable shields, is located on the interface plate of
the system unit.
3.5.4.4 Updating firmware
The firmware is a component of Automation Studio. The module is updated to this version automatically.
To update the firmware included in Automation Studio, the hardware must be upgraded (see "Project manage-
ment" / "The workspace" / "Upgrades" in the Automation Studio help system).
Panel PC 2100 user's manual V1.11
Table 141: System stop error codes
...150 ms
...600 ms
2 second delay
Technical data • Individual components
Error code indicated by red Status LED
•
•
•
-
Pause
•
-
•
•
-
Pause
-
•
•
-
Pause
•
•
-
Pause
145