Technical data • Complete system

2.2.2 Humidity

The following table lists the minimum and maximum relative humidity values (non-condensing) for the individual
components that are relevant for the humidity limitations of a complete system. The lowest and highest common
values are always used when establishing these limits.
Display type
Model number
12.1" single-touch
5AP923.1215-00
15.0" single-touch
5AP923.1505-00
19.0" single-touch
5AP923.1906-00
15.6" multi-touch
5AP933.156B-00
18.5" multi-touch
5AP933.185B-00
21.5" multi-touch
5AP933.215C-00
24.0" multi-touch
5AP933.240C-00
Display type
Model number
5.7" single-touch
5AP1120.0573-000
5.7" with keys
5AP1151.0573-000
7.0" single-touch
5AP1120.0702-000
10.1" single-touch
5AP1120.101E-000
10.4" single-touch
5AP1120.1043-000
10.4" single-touch with keys
5AP1180.1043-000
10.4" single-touch with keys
5AP1181.1043-000
10.4" single-touch with keys
5AP1182.1043-000
12.1" single-touch
5AP1120.1214-000
12.1" single-touch
5AP1120.121E-000
15.0" single-touch
5AP1120.1505-000
15.0" single-touch with keys
5AP1180.1505-000
15.6" single-touch
5AP1120.156B-000
19.0" single-touch
5AP1120.1906-000
Component
Model number
System units
5PPC2100.BYxx-000
5CFAST.xxxx-00
CFast cards
5CFAST.xxxx-10
5ACCIF01.FPCC-000
5ACCIF01.FPLK-000
5ACCIF01.FPLS-000
Interface options
5ACCIF01.FPLS-001
5ACCIF01.FPSC-000
5ACCIF01.FPSC-001
5ACCIF01.ICAN-000
The specifications listed correspond to the relative humidity (non-condensing) at an ambient temperature of 30°C.
More detailed information about specific temperature-dependent humidity values can be found in the technical data
for the individual components.
34
Operation
5 to 90%
8 to 90%
5 to 90%
5 to 90%
5 to 90%
10 to 90%
5 to 90%
Table 25: AP9x3 display units - Humidity
Operation
5 to 90%
5 to 90%
20 to 90 %
20 to 90 %
5 to 90%
5 to 80 %
5 to 80 %
5 to 80 %
20 to 90 %
5 to 90%
8 to 90%
8 to 90%
5 to 90%
5 to 90%
Table 26: AP1000 display units - Humidity
Operation
5 to 90%
Max. 85% at 85°C
10 to 95%
5 to 90%
5 to 90%
5 to 90%
5 to 90%
5 to 90%
5 to 90%
5 to 90%
Table 27: System units, IF options, CFast cards - Humidity
Storage
5 to 90%
8 to 90%
5 to 90%
5 to 90%
5 to 90%
10 to 90%
5 to 90%
Storage
5 to 90%
5 to 90%
10 to 90%
10 to 90%
5 to 90%
5 to 90%
5 to 90%
5 to 90%
10 to 90%
5 to 90%
8 to 90%
8 to 90%
5 to 90%
5 to 90%
Storage
5 to 95%
Max. 85% at 85°C
Max. 85% at 85°C
10 to 95%
5 to 95%
5 to 95%
5 to 95%
5 to 95%
5 to 95%
5 to 95%
5 to 95%
Panel PC 2100 user's manual V1.11
Transport
5 to 90%
8 to 90%
5 to 90%
5 to 90%
5 to 90%
10 to 90%
5 to 90%
Transport
5 to 90%
5 to 90%
10 to 90%
10 to 90%
5 to 90%
5 to 90%
5 to 90%
5 to 90%
10 to 90%
5 to 90%
8 to 90%
8 to 90%
5 to 90%
5 to 90%
Transport
5 to 95%
10 to 95%
5 to 95%
5 to 95%
5 to 95%
5 to 95%
5 to 95%
5 to 95%
5 to 95%