System stop error codes
Incorrect configuration or defective hardware can cause a system stop error.
The error code is indicated by the red Error LED using four switch-on phases. Each switch-on phase has a duration
of either 150 ms or 600 ms. The error code is repeated every 2 seconds.
Error description
RAM error:
The interface is defective and must be replaced.
Hardware error:
The interface or a system component is defective and must be replaced.
Key
Pause
3.5.6.4 Updating firmware
The firmware is a component of Automation Studio. The module is updated to this version automatically.
To update the firmware included in Automation Studio, the hardware must be upgraded (see "Project manage-
ment" / "The workspace" / "Upgrades" in the Automation Studio help system).
Panel PC 2100 user's manual V1.11
Table 170: System stop error codes
...150 ms
...600 ms
2 second delay
Technical data • Individual components
Error code indicated by red Status LED
-
Pause
-
-
Pause
-
-
Pause
-
Pause
159