Korg NAUTILUS Series Parameter Manual page 695

Hide thumbs Also See for NAUTILUS Series:
Table of Contents

Advertisement

4. Verify the settings. Then press the OK button to
execute, or press the Cancel button to cancel.
Change all bank references
This command changes all program banks specified for
timbres in combinations or tracks of songs.
1. Select "Change all bank references" to open the dialog
box.
2. If you wish to change bank references for
combinations, check "Combination."
If you wish to change bank references for songs, check
Song.
3. In "Program Bank," specify the replacement for each
bank.
4. To execute the Change All Bank References
command, press the OK button. To cancel, press the
Cancel button.
If you change two or more different banks to the same
bank, it will not be possible to use this function to change
them back to different banks. Be careful that the change
destination banks do not overlap.
Touch Panel Calibration
If input via the LCD screen does not work as you expect, or
if the edit cell moves to a location other than where you
pressed the LCD screen, use this command to adjust the
sensitivity of the LCD screen.
1. Select "Touch Panel Calibration" to open the dialog
box.
2. If you are unable to select this command from the
page menu, go to the Basic Setup page, and then hold
GLOBAL: Page Menu Commands Change all bank references
down the ENTER button and press QUICK ACCESS
D button. This will call up the calibration dialog.
3. Press the square in the upper left of the LCD. When
your touch has been detected correctly the square will
be highlighted.
4. Press the square in the lower right of the LCD. When
your touch has been detected correctly the square will
be highlighted.
5. Press the Done button.
If your touch was not detected correctly, an error message
will appear. Please perform the procedure once again.
Half Damper Calibration
If a damper pedal that supports half damper (the DS–1H
option) is connected to the DAMPER jack, here's how you
can adjust the sensitivity if the damper effect is not applied
appropriately.
Since the half-damper pedal is highly sensitive, please
use the optional DS–1H. Other pedals may not produce
the appropriate effect, or may be impossible to calibrate
correctly.
1. Connect a half-damper pedal to the DAMPER jack.
2. Select "Half Damper Calibration" to open the dialog
box.
3. Press the half-damper pedal, and then release your
foot from the pedal.
4. Press the Done button.
If the adjustment could not be performed correctly, an
error message will be displayed. Please perform the
procedure once again.
685

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nautilus-61

Table of Contents