Operating Instructions
Single-pole conductor-rail system
SingleFlexLine Program 0815
Fault
Insulating profile is not en-
gaged in the hanger clamp.
BAL0815-0002d-US
www.conductix.us
Cause
Collision with system components
Abrasive dust has collected at one of the more frequently
used transfer points (where the direction of travel is re-
versed).
Conductor-rail has not been properly fitted.
Use of damaged components.
translated document
Corrective measures
cable, replace if necessary. Check
the installation position at various
points in the system.
Check the system's layout, fasten
the affected components in such a
way that they cannot be collided
with, replace damaged compo-
nents.
Adjust the consumer's movement
profile. Move over the end position
to push the collected abrasive dust
out of the power rail. Clean the
power rail.
Snap in the insulation profile,
check components, replace if nec-
essary
Replace damaged components.
page 86 of 94