Operating Instructions
Single-pole conductor-rail system
SingleFlexLine Program 0815
3 Technical specifications
3.1 Electrical
Rated current for the overall system
Rated current for current
collectors*
Nominal voltage
Ohmic resistance at 35°C
Impedance at 14 mm pin spacing
Number of pins
Assignment
Conductor-rail cross chapter
Conductor material
Protection class
*Current-carrying capacity depending on the current-collector type! The current-carrying capacity is defined by the connected cable
and is generally lower (see catalog)! Ambient temperatures and operating modes result in reduced current-carrying capacity (e.g.,
operating at a standstill, operating at elevated temperature).
3.2 Mechanical
Max. travel speed
Ambient temperature
Maximum air humidity at +40°C
Max. operating temperature difference
Altitude above sea level
Installation situation/environment
Direction of travel
Pin spacing
3.2.1
Lengths
Max. length of the installed conductor-rail
Power rails
Min. permissible power rail length
Supplementary length per connection point
BAL0815-0002d-US
www.conductix.us
Single current collector
Dual current collector
without protective earth
with protective earth (PE)
10–54 A as an overall system with expansion elements; (conductor-
rails: 10–100 A)
Pure carbon: max. 16 A
Copper–graphite: max. 35 A
Pure carbon: 2 x 16 A
Copper–graphite: max. 2 x 25 A
max. 48 V AC/DC
max. 500 V AC
0.745
Ω/1000 m
0.748
Ω/1000 m
Any (EMS system holder 2, 4, 6, 8, 10 pin)
Protective earth (PE) 4. Pin from above
25 mm
2
Copper
IP 2X contact protected to IEC 60529
Uninterrupted linear track 400 m/min
–5°C to +55°C
50 % RH
40 K (in the ambient temperature range)
≤ 2000 m
Horizontal rail alignment/ interior (not vertical)
Forwards and backwards (reversing)
Engagement of the current collector from the bottom or from the side
14 mm
Any, depending on the power feed design
max. 4000 mm (standard), 6000 mm and short lengths on request
300 mm
10 mm
translated document
page 18 of 94
Need help?
Do you have a question about the SingleFlexLine Program 0815 and is the answer not in the manual?