Required protective equipment:
Danger of sensitization, irritation of the mucous membranes, and respiratory diseases due to
dust!
Dust from the collector brushes collects in the conductor-rails and the guide profile. This dust is very
DANGER!
fine and is categorized as a health risk. Working a lot with the conductor-rail system and/or not apply-
ing the requisite level of care when handling accumulated dust (e.g. cleaning the system with com-
pressed air) can lead to sensitization. People who frequently spend longer periods of time in a heavily
used plant without protective equipment must expect the following consequences:
→ In workplaces with long-term exposure and heavily trafficked plants, take effective measures to pro-
→ Personal protective equipment must be worn during all works on the conductor-rail system during
→ The following personal protective equipment must be worn during cleaning operations:
→ Before starting work, clean the conductor-rail in accordance with regulations (see WV0800-0001)
→ Protect the surroundings during cleaning work, for instance by covering or removing warehouse
→ Do not blow out dust with compressed air. Instead, vacuum it up. The vacuum cleaner must be
→ Do not eat and/or drink while cleaning!
→ Do not smoke while cleaning!
Risk of explosion!
Airborne dust, open flames or other sources of ignition create result in explosion.
ATTENTION!
The following table covers the most usual test steps. You can find details for cleaning and maintenance in WV0800-0001 and
WV0800-0002. The cleaning interval is individual and depends on the degree of contamination and the intensity of the use of the
system. Do not remove the patina under any circumstances! You can find details on the use of copper rails in WV0800-0004.
BAL0815-0002d-US
www.conductix.us
Irritations of the mucous membranes
Respiratory diseases
Cancer
tect employees from the dust.
which accumulated dust is disturbed
Safety goggles
Dust mask class FFP3
Protective gloves
Disposable coverall
goods and blocking access to those areas in which dust could fall down on persons
equipped with a Class H fine filter
translated document
page 78 of 94